Example from the Building Standards Library

Question: What wind speed must a tornado safe room be designed for?

Building Standards Library
Imani VanceStructural engineer
Subscriber
Strong match

A tornado safe room is designed to one of four wind speeds, set by the site’s zone citation 1:

Zones
130, 160, 200 or 250 mph, by zone on the tornado map citation 1
Basis
A 3-second gust at 33 feet above grade, Exposure C citation 2
Editions
The third edition (2015) lists the same four speeds citation 3
FEMA P-361 (2021)p.B3-9FEMA P-361 (2015)p.B3-6
3 tiers searched · 2 pages citedCited
Marcus ReyesBuilding official
Member
Strong match

The newest edition on file (2021) sets four tornado design wind speeds, by zone citation 1:

Zones
130, 160, 200 or 250 mph, by zone on the tornado map citation 1
Basis
A 3-second gust at 33 feet above grade, Exposure C citation 2
Map
The tornado map follows ICC 500-2020 and is very similar to the one first published in 2000 citation 3
FEMA P-361 (2021)p.B3-9
2 tiers searched · 1 page citedCited
Rosa EllisonHomeowner
Public
Partial match

The home safe-room designs in FEMA P-320 use one wind speed, 250 mph citation 1:

Design speed
250 mph, for the tornado and hurricane designs in the booklet citation 1
Walls and roof
Resist wind-borne debris, stay anchored and remain standing citation 2
FEMA P-320 (2014)p.15p.22
1 tier searched · 2 pages citedCited

Examples are built on public documents; access tiers are simulated.

The public and members need different answers.

A homeowner and a building official can ask the same question. The homeowner should get the public guidance; the official should get the design standard. Running two assistants means two sets of content to maintain.

How Chairlift handles it

  1. Public guidance sits in the public tier; standards sit in the member and subscriber tiers.
  2. The same question searches different documents depending on who asks.
  3. Both answers cite their page, so each person can check the source they’re entitled to.

One library. Each person searches only their part.

Every answer above was written from the documents lit for that person. Nothing locked was searched.

Each document in the Building Standards Library, whether each person’s grants open it, and whether their answer cited it.
DocumentImaniSubscriberMarcusMemberRosaPublic
FEMA P-320 (2014) PublicOpensOpensCited
FEMA P-361 (2021) MemberCitedCitedLocked
FEMA P-55 (2011) MemberOpensOpensLocked
FEMA P-749 (2022) MemberOpensOpensLocked
FEMA P-361 (2015) SubscriberCitedLockedLocked
FHWA-NHI-21-002 SubscriberOpensLockedLocked

Organizations that serve the public and members

  • Codes and standards organizations
  • Building-safety associations
  • Public-facing professional societies
  • Consumer and member help desks

See it on your own library.

30 minutes, with your documents and your tiers.